Door / Window Contact Sensor

This article contains instructions for programming a Door / Window Contact Sensor with the GSM system.

NOTE: If you purchased the sensor as part of a kit, then it has been pre-programmed to the main panel already, and no other programming is needed. Follow these steps below if you have purchased a sensor separately, and are now adding it to an existing system.

Door / Window Contact SensorDoor / Window Contact Sensor

Programming a Door/Window Contact Sensor with the GSM Main Panel:

  1. Turn off any motion detectors to prevent accidentally programming them.
  2. On the Main Panel, enter your 6-digit SET password, then press Enter.
  3. Scroll to the right using the '6' key to select Zone, and press Enter.
  4. Select an appropriate Zone for the sensor. By default, Zone 1 is used for Door / Window Contact Sensors.
  5. With 'Coding' selected, press Enter.
  6. Trigger the sensor by moving it away from the magnet.
  7. On the Main Panel, a string of zeros will be replaced by another string of numbers. Press Enter.
  8. Return to the main screen using the ESC key.
  9. Turn on any motion detectors that were turned off.

See more about Zones in the GSM User Manual, Page 98